Skip to main content

Table 2 Reported sequences and normal myocardial T1ρ values in healthy subjects according to sequences and field strengths

From: Magnetic resonance myocardial T1ρ mapping

Study

Year

Magnet

System

Sequence

Spin-lock module

Number of subjects*

Age (y)

Normal T1ρ (ms)

     

Scheme

#TSL

Amplitude

   

van Oorschot J et al. [83]

2014

3.0-T

Achieva, Philips

2D SSFP

Cluster 1

4

750 Hz

5 (0)

25 ± 3

50.0 ± 3.0

Wang C et al. [81]

2015

3.0-T

Trio, Siemens

2D GRE

Cluster 1

3

341 Hz

8 (5)

43 ± 10

42.2 ± 11.6

Wang L et al. [57]

2016

3.0-T

Verio, Siemens

2D GRE

NR

5

400 Hz

35 (20)

41 ± 14

49.4 ± 22.6

Berisha S et al. [59]

2016

1.5-T

Avanto, Siemens

2D SSFP

Cluster 1

7

500 Hz

10 (3)

29 ± 7

64.5 ± 2.1

van Oorschot J et al. [53]

2016

1.5-T

Ingenia, Philips

2D SSFP

Cluster 1

5

500 Hz

10 (2)

27 ± 3

52.8 ± 1.8

van Oorschot J et al. [53]

2016

3.0-T

Achieva, Philips

2D SSFP

Cluster 1

5

500 Hz

10 (6)

30 ± 3

46.4 ± 1.8

van Oorschot J et al. [56]

2017

3.0-T

Achieva, Philips

3D GRE

Cluster 1

5

500 Hz

8 (2)

51 ± 6

51.5 ± 1.2

Kamesh Iyer S et al. [55]

2019

1.5-T

Avanto, Siemens

3D SSFP

Cluster 1

12

500 Hz

6 (NR)

NR

67.9 ± 4.5

Qi H et al. (53)

2020

1.5-T

Aera, Siemens

3D SSFP

Cluster 2

5

400 Hz

11 (5)

30 ± 3

58.0 ± 4.1

Bustin A et al. [42]

2021

1.5-T

Aera, Siemens

2D SSFP

Cluster 2

5

500 Hz

8 (3)

30 (24–40)

47.7 ± 4.0

Thompson EW et al. [80]

2021

1.5-T

Avanto, Siemens

2D SSFP

Cluster 1

7

400–500 Hz

10 (6)

51 (38–55)

65.4 ± 5.2

Deng W et al. [107]

2022

1.5-T

Ingenia, Philips

2D SSFP

Cluster 1

4

400 Hz

57 (28)

27 ± 12

47.9 ± 2.8

  1. Cluster 1: \({90}_{x}-S{L}_{-y}-{180}_{-y}-S{L}_{-y}-{90}_{-x}\). Cluster 2: \({90}_{x}-S{L}_{y}-{180}_{y}-S{L}_{-y}-S{L}_{y}-{180}_{-y}-S{L}_{-y}-{90}_{-x}\). *Number in parentheses indicates number of female subjects. GRE, gradient echo; NR, not reported; SSFP, steady-state free precession; TSL, spin-lock time