Skip to main content

Table 2 Detailed parameters of the turbo fast low-angle shot 3D sequence used in the conventional-WBMRA protocol

From: Subtractionless compressed-sensing-accelerated whole-body MR angiography using two-point Dixon fat suppression with single-pass half-reduced contrast dose: feasibility study and initial experience

Parameter

Station I

Station II

Station III

Station IV

Station V

Repetition time (TR, ms)

3.9

3.9

3.9

3.9

3.9

Echo time (TE, ms)

1.29

1.26

1.26

1.34

1.40

Flip angle (FA, °)

20

20

20

20

20

Field of view (FOV, mm2)

450 × 450

450 × 450

450 × 450

450 × 450

450 × 450

Voxel size (mm3)

1.1 × 1.2 × 1.2

1.2 × 1.2 × 1.5

1.2 × 1.2 × 1.5

1.0 × 1.0 × 1.0

0.9 × 0.9 × 1.0

Slice number

125

125

125

130

110

Sense acceleration factor

4.3

4

4

4.5

4.5

Bandwidth (Hz)

1225.5

1329.8

1329.8

1106.2

1000

k-space filling mode

Centra

Centra

Centra

Centra

Centra

Phase partial Fourier

0.75

0.75

0.75

0.75

0.75

Need for breath-hold

Yes

Yes

No

No

No

Acquisition time (s)

18.2

20

20

20

18.7

  1. WBMRA whole body MR angiography